Flameshield 5000 Blowout Preventer Hose
5,000psi W.P. – 10,000 psi Test-15,000 Minimum Burst
Certification/Standards:
API Spec 16D--ISO 14693
Recommended For:
When primary well control has been lost, it becomes the function of the BOP to operate
and seal the well to prevent a blowout. All equipment must be able to operate under fire exposure
conditions.Flameshield 5000 is a hydraulic control hose that operates at 5,000psi
whilst exposed directly to fire for a minimum of 5 minutes ensuring all well control operations
can be effected in an emergency situation.
Tube: Modified Nitrile. Black.
Reinforcement:
Multiple layers of textile fabric and steel cable, with one layer middle rubber placed between cable layers.
Cover:
Fire resistant, rubber cover, stainless steel armored to handle abrasion, corrosion, cutting, gouging, oil and weather.
Couplings: Crimped couplings with over-ferrule fire protection.
Temperature:-40°C to +121°C)
Options: Accessories such as API 16D quick connector, self-sealing union and exterior armor to protect hoses
against extreme environmental damage are available upon request.
Test:
Each hose is tested at 10000psi for 15 minutes. Pressure test graph, test certificate and letter of conformance are issued for each hose.
Specification